Plex V

Exclusive thermal process

Manufactured using an exclusive thermal process. All metalurgic transitions as austenite and martensite phases are take at room temperature, giving many benefits against other NITI file

Controlled memory wire

Controlled memory wire allows us to respect the root canal anatomy, avoiding root weakening and the creation of ledges and transportation of canal perforations.

High Resistance

CM wire alloy with special heat treatment gives a very high resistance and flexural fatigue.

Pre-curved

It can be pre-curved and has an extreme efficiency in the most curved canals.

Orodeka Files for dental care precision

Shape memory

Shape memory permits the file to recover its original shape when sterilised, retrieving all the metallic properties and it’s metalurgic structure

Triangular Convex Section

The instrument section is a triangular convex modified, it facilitates the removal of debris and reduces contact with the canal walls with a very active cutting efficiency.

+70% of flexibility Pre-curved

Can be pre-curved and is extremely effective in the most curved channels

+40% of resistance High resistance

CM alloy with a specific heat treatment, provides very high strength and bending very high strength and bending fatigue.

WHY USE PLEX-V?

  • Manufactured using an exclusive thermal process. All metalurgic transitions as Austensite and martensite phases, take place at room temperature, giving many benefits against other NiTi files.
  • Have controlled memory wire this allows us to respect the root canal anatomy, avoiding root weakening and the creation of ledges, transportation or canal perforations.
  • CM wire alloy with special heat treatment give very hig resitance to torsional and flexion fatigue.
  • Can be pre-curved and show extreme efficiency in the most curved canals.
  • Have shape memory, material recovers its original shape when sterilised, retrieving all the metallic properties, and its metalurgic structure.
  • The instrument section is triangular convex modified, facilities the removal od debris and reduces contact with the canal walls, with a very active cutting efficiency.

Tip Design

A non active tip without blades, with no cutting function only for scouting.

Advantages

Avoids the creation of ledges and perforations of the root canal walls.

Cross Section

– Unique 3s cross section

– Three sharps cutting blades

– Respect the original anatomy

Advantages

Large and deep debris removal space, respecting the original root canal anatomy

Pitch Design

– lncreased gradually from the file tip.

– Removes dentine debris from the root canal to the pulp chamber.

Advantages

Avoids Breakings, stucking and gives more control inside the root canals.

Products

Plex V – 06 – Easy Canals
MODEOPENPATH FILESFINISHING
TAPER08030506
DIAMETER15152025
LENGTH19mm21mm - 25mm - 28mm - 31mm
TORQUE2.5 N.Cm1.5 N.Cm2.5 N.Cm2.5 N.Cm
SPEED500 RPM300 RPM500 RPM500 RPM
Plex V – 04 – Difficult Canals
MODEOPENPATH FILESFINISHING
TAPER08030404
DIAMETER15152025
LENGTH19mm21mm - 25mm - 28mm - 31mm
TORQUE2.5 N.Cm1.5 N.Cm2.5 N.Cm2.5 N.Cm
SPEED500 RPM300 RPM500 RPM500 RPM

Hand Use File

ROOT CANAL K-FILES

To Give Operators a smooth tacticle sense inside the root canal packed with 6 files per box, acaible of single of assorted size made of stainless steel 

Size21mm25mm28mm31mm
06
K00621K00625K00628K00631
08K00821K00825K00828K00831
010K01021K01025K01028K01031
015K01521K01525K01528K01531
020K02021K02025K02028K02031
025K02521K02525K02528K02531
030K03021K03025K03028K03031
035K03521K03525K03528K03531
040K04021K04025K04028K04031
015 - 040KA21KA25KA28KA31
045 - 080KB21KB25KB28KB31

ROOT CANAL H-FILES

To pool back the agnail function after touchdown. the whorl depth increases with the taper, creating a sharper, more flexible instrument packed with 6 files per box, acaible of single or assorted size made of stainless steel

Size21mm25mm28mm31mm
06H00621H00625H00628H00631
08H00821H00825H00828H00831
010H01021H01025H01028H01031
015H01521H01525H01528H01531
020H02021H02025H02028H02031
025H02521H02525H02528H02531
030H03021H03025H03028H03031
035H03521H03525H03528H03531
040H04021H04025H04028H04031
015-040HA21HA25HA28HA31
045-080HB21HB25HB28HB31

ROOT CANAL K-REAMERS

To pool back the agnail function after touchdown. the whorl depth increases with the taper, creating a sharper, more flexible instrument packed with 6 files per box, acaible of single or assorted size made of stainless steel

Size21mm25mm28mm31mm
06R00621R00625R00628R00631
08R00821R00825R00828R00831
010R01021R01025R01028R01031
015R01521R01525R01528R01531
020R02021R02025R02028R02031
025R02521R02525R02528R02531
030R03021R03025R03028R03031
035R03521R03525R03528R03531
040R04021R04025R04028R04031
015-040RA21RA25RA28RA31
045-080RB21RB25RB28RB31

3D Teeth

Heat resistant

Polimers used are heat-resistant, so high-speed burs don’t gum up and the replica’s canal walls don’t melt when obturating with warm gutta-percha methods.

Special patented resin

Real size tooth models made out of special patented resin material with hardness similar to dentin and that enables visual control of files during preparation

Multiple positions

Number and morphological position of root canals copies real tooth. There are a number of procedural endodontic challenges;S curves, cervical curves, mid-root bifurcations, apical confluencies etc.

Root Canals

Root canals contain a red gel-like material simulating pulp tissue that dissolves in sodium hypochlorite. It is possible to learn the access through calcified pulp chambers.

Endodontic simulator

Endodontic simulator for training the access to the pulp chamber and root canal preparation tasks.

Plex Box

Multi-functional root canal file box

Operating instructions

The multi-functional root canal file box is made of stainless steel, and there are several holes and slots for measuring the length of the root canal file on the product, which plays the role of recording the number of root canal files and measuring the length of the root canal files. Passive products. Non-sterile .

Indication for use

Used for recording the number of root canal files and measuring the length of root canal files.

The period of validity

Long-term

Usage:

  • Place the used root canal file in the placement hole on the file box Number of rotation, recording dial

  • Place the root canal file that needs to measure the length into the length measuring slot on the file box.

Notes:

  • Non-sterile, please disinfect before use. 134°C steam disinfects 30min.

  • Rinse with distilled water before disinfection after use

  • The product should be operated by trained physicians

  • Do not use the product for other purpose 

  • For a single patient to avoid cross-infection.

Disinfection method, storage method:

Cleaning:

Rinse dirt with flowing distilled water and wash dirt on the surface of instruments with soft brushes.bus leo.

Packaging:

Blister pack of 4 Files

Disinfection:

134C steam disinfection, 30min

Storage:

Equipment should be stored in a clean, dry and ventilated room